{"id":4101,"date":"2025-07-09T11:00:36","date_gmt":"2025-07-09T09:00:36","guid":{"rendered":"https:\/\/lindhautomation.com\/?p=4101"},"modified":"2025-07-11T12:46:57","modified_gmt":"2025-07-11T10:46:57","slug":"vardet-av-repetition-darfor-behovs-repeaters-i-profibus-natverk","status":"publish","type":"post","link":"https:\/\/lindhautomation.com\/en\/vardet-av-repetition-darfor-behovs-repeaters-i-profibus-natverk\/","title":{"rendered":"On repeat: the continuing value of repeaters for PROFIBUS networks"},"content":{"rendered":"<p>Repeaters are one of the most important devices in the arsenal of tools for managing PROFIBUS networks. By receiving, refreshing, and forwarding the fieldbus communication signal, repeaters amplify the data transmission to successfully reach its destination on the network. They\u2019re required for any PROFIBUS network with cables longer than 200 meters or a series of more than 31 devices.<\/p>\n\n\n\n<p>While repeaters have long been a part of industrial automation, they\u2019re top-of-mind for many who work with PROFIBUS these days. Siemens recently announced the company <a href=\"https:\/\/support.industry.siemens.com\/cs\/document\/109977618\/information-about-product-phase-out-of-profibus-standard-and-diagnostic-repeaters-as-well-terminating-resistor?dti=0&amp;lc=en-US\" target=\"_blank\" rel=\"noopener\"><em><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-ast-global-color-1-color\">was phasing out its PROFIBUS repeaters<\/mark><\/em><\/a>, which will be completely off the market by October 2026. Thankfully, manufacturers like Indu-Sol are still producing these critical devices.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>Why are PROFIBUS repeaters important?<\/h2>\n\n\n\n<p>PROFIBUS has been a standard communications protocol for automation networks since the '90s. Although there are newer standards like PROFINET today, plenty of production lines still use PROFIBUS and have no plans to switch anytime soon. And repeaters are essential for keeping those PROFIBUS networks up and running.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>Using repeaters to extend PROFIBUS networks<\/h2>\n\n\n\n<p>Repeaters are typically added to a PROFIBUS network when the owner wants to extend it. Maybe they\u2019ve bought a new part for a machine \u2014 some new cylinders or new motors to be controlled. Maybe they have a new product and need to change the line. No matter what, a repeater is usually necessary to include a new addition to a network.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>Using PROFIBUS repeaters to rebuild networks<\/h2>\n\n\n\n<p>Another condition for installing repeaters is when PROFIBUS networks are being rebuilt. After many years of operation, it\u2019s quite common for an industrial automation network to need an overhaul of some kind or another. There can often be an accumulation of issues affecting production, either from when the network was first created or as it was updated over time. Incorporating one or more repeaters into the rebuilt network can not only address those issues but also help prevent future problems. With multi-channel repeaters, it\u2019s possible to create a star-structured network, splitting a line into segments for each device or series of devices with a similar purpose. It\u2019s a network topology with numerous advantages that ensure more stable operation, including the ability to separate interference-prone components and zero in on and diagnose errors.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>Using PROFIBUS repeaters for troubleshooting networks<\/h2>\n\n\n\n<p>An additional benefit that comes with having a repeater installed on a PROFBUS network is how much easier it makes troubleshooting. By creating separate segments with termination on either end in the network \u2014 with a repeater in the middle \u2014 it takes much less effort to find and debug errors.<\/p>\n\n\n\n<p>However, not all PROFIBUS repeaters enable easier troubleshooting equally. Multi-channel repeaters create more segments that separate devices and thus more specificity on the error\u2019s location than single-channel repeaters. But there are other aspects as well. A frequent complaint about some models of repeaters (including the soon-to-be-retired Siemens repeaters) is the use of screw terminals instead of connectors. A repeater with connectors can allow diagnostic devices to link with the network and monitor incoming and outgoing signals for any errors.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><a><\/a>Indu-Sol\u2019s MULTIrep PROFIBUS repeaters<\/h2>\n\n\n\n<p><em><a href=\"https:\/\/www.indu-sol.com\/en\/products\/profibus\/infrastructure-components\/repeater\/multirep\/\" target=\"_blank\" rel=\"noopener\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-ast-global-color-1-color\">Indu-Sol\u2019s line of MULTIrep repeaters is<\/mark><\/a> <\/em>is ideal for any PROFIBUS network upgrade, extension, or overhaul. Not only do they meet all the necessary PROFIBUS requirements and link to the network through connectors, but they also feature integrated quick diagnosis and error filtering. \nEvery MULTIrep repeater constantly monitors PROFIBUS telegram traffic and indicates if it detects any bus or data errors through status LEDs on the device. This enables even quicker and easier network troubleshooting that narrows down the affected segments at a glance.<\/p>\n\n\n\n<p>So, while some manufacturers are closing down their production of repeaters for PROFIBUS networks, others are still going strong and even adding a level of innovation to their versions of the device.<\/p>\n\n\n\n<p class=\"translation-block\">At <a href=\"https:\/\/lindhautomation.com\/en\/\" target=\"_self\"><em><mark class=\"has-inline-color has-ast-global-color-1-color\">Lindh Automation<\/mark><\/em><\/a>, we help our customers make informed choices that reduce long-term maintenance costs and simplify troubleshooting. We\u2019ve seen firsthand how much impact a repeater can have on the stability of a PROFIBUS network.<\/p>\n\n\n\n<p><em>Got questions about PROFIBUS repeaters, segmentation, or diagnostics? Reach out to Mattias Lindh directly \u2014 we\u2019re here to help.<\/em><\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Repeaters \u00e4r oumb\u00e4rliga verktyg f\u00f6r att s\u00e4kra ett v\u00e4lfungerande PROFIBUS-n\u00e4tverk. Deras uppgift \u00e4r att ta emot och skicka vidare datakommunikation, samtidigt som de f\u00f6rst\u00e4rker signalen s\u00e5 att den kan n\u00e5 sin destination i n\u00e4tverket. Om ett PROFIBUS-n\u00e4tverk har \u00f6ver 200 meter kablar eller en serie med fler \u00e4n 31 enheter \u2013 d\u00e5 \u00e4r repeaters ett [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":4108,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4101","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-allmant"],"_links":{"self":[{"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/posts\/4101","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/comments?post=4101"}],"version-history":[{"count":5,"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/posts\/4101\/revisions"}],"predecessor-version":[{"id":4114,"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/posts\/4101\/revisions\/4114"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/media\/4108"}],"wp:attachment":[{"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/media?parent=4101"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/categories?post=4101"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lindhautomation.com\/en\/wp-json\/wp\/v2\/tags?post=4101"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}